DSSU666 series three phase three wire electronic energy meter (DIN Rail)
Summary:
D?SU666 series electronic energy meter is designed for power monitoring and energy measurement such as power system, communication industry, construction industry, etc. to be a new generation of programmable intelligent instrument, integrated with measurement and communication function, mainly used for real-time measurement and display for the electrical parameters such as voltage, current, active power, reactive power, frequency, power factor, energy in the electrical circuit, etc.
1?Main functions and characteristics
?DIN35mm Standard DIN-Rail, seven modulus with segment LCD display
?Measurement function: Characterized with measurement for three phase three wire voltage, current, frequency, active power, power factor, active energy and reactive energy
?communication function: RS485 communication interface, supporting DL/T645-2007 protocol, customizable for MODBUS-RTU protocol
?Multi-rate function: it supports four rates including top, peak, flat, valley rate.
2?Specification and type selection:
Product function | Model | |||
DSSU666 | DSSU666-D | DSSU666-F | ||
Voltage input | Direct input | AC 3×380V | ||
Current input | Direct input | 5(80)A | ||
Via CT/PT | 1.5(6)A | |||
Voltage, current, power, reactive power, frequency, power factor | NO | YES | ||
Energy | Active energy | YES | ||
Reactive energy | YES | |||
Bidirectional measurement | NO | YES | ||
Multi-rate(clock) | NO | YES | ||
Others | Demand | NO | YES | |
Power impulse output | YES | |||
Communication | IR | NO | YES | |
RS485 | YES | |||
Display mode | Two lines 7 segment LCD | |||
Dimension | L×W×H(mm) | 126×89×66 7 modulus |
Note: RS485 communication is assumed to be DL/T645-2007 protocol, customizable for Modbus-RTU protocol.
3?Main technical performance and parameters
Technical parameters | Index | |||
Input signal |
voltage | Wiring mode | Three phase three wire | |
Voltage specification | AC 3×380V | |||
Specified working voltage range | 0.9Un~1.1Un; the extensional work voltage range: 0.8Un~1.2Un | |||
Consumption of the voltage circuit | =5VA/1W(each phase) | |||
Resistance | >500kO(each phase) | |||
Current | Rated value | Via PT/CT input AC1.5(6)A | ||
Direct input AC 5(80)A | ||||
Current overload | Input via PT/CT: instant:201max, time of application: 0.5S | |||
Direct input: instant:301max, time of application: half cycle of the rated frequency | ||||
Consumption of the current circuit | =2VA(each phase) | |||
Resistance | <20mO(each phase) | |||
Frequency | Input range | (50±5%)Hz | ||
Clock | Battery capacity | =1200mAh | ||
Accuracy of clock(day error) | =0.5s/d(23?) | |||
Output | Display | Segment LCD | ||
Measurement parameters & grade | Voltage: Class 0.5; Current: Class 0.5; Power factor: Class 1;Frequency: Class 0.5; Active power: 1.5(6)A Class 0.5/5(80)A Class 1; Reactive power :Class 1; Activeenergy: 1.5(6)A Class 0.5/5(80)A Class 1; Reactive energy: Class 2; | |||
Energy | Multi-rate energy | Support positive/negative total active/reactive multi-rate measurement function | ||
Four-quadrant energy | Support reactive four quadrant energy measurement function | |||
Max. demand record | Support positive/negative total active/reactive max. demand record, demand cycle and slip time can be set | |||
Pulse constant | AC3×380V AC1.5(6)A 6400imp/kWh(imp/kvarh) | |||
AC3×380V AC5(80)A 400imp/kWh(imp/kvarh) | ||||
Pulse signal output | Provide 1 set(active/reactive energy) optical signal and optocoupler isolated open collector electrical signal pulse output, pulse length:80ms±16ms | |||
Communication | RS485 communication | Support MODBUS-RTU or DL/T645-2007 communication protocol(switchable), the communication baud rate 1200bps, 2400bps,4800bps,9600bps can be set, assumed to be 9600bps | ||
IR communication(*) | Support MODBUS-RTU or DL/T645-2007 communication protocol(switchable), Infrared wavelength: 900nm~1000nm communication baud rate:1200bps communication angle: =±15° communication distance:=4m |
Note:
1. The meter can only be the same as its corresponding technical performance and parameters.
2. The items remarked * is the optional items, which shall be specified by the customers while ordering.
- DIN Rail Kwh Meter Single Phase 1 Pieces / (Min. Order)
- DDSID666 Single Phase Smart Meter 5 Pieces / (Min. Order)
- Data Acquisition 1 Pieces / (Min. Order)
- Data Terminal 1 Pieces / (Min. Order)
- Active Energy Meter 1 Pieces / (Min. Order)
- 3 Phase Amp Meter 1 Pieces / (Min. Order)
- DIN Rail Kwh Meter Single Phase 1 Pieces / (Min. Order)
- True RMS Clamp Meter 1 Pieces / (Min. Order)
- AC DC Clamp Meter 1 Pieces / (Min. Order)
- 3 Phase Clamp Meter 1 Pieces / (Min. Order)
- Multimeter Digital 1 Pieces / (Min. Order)
- Multifunction Meter 1 Pieces / (Min. Order)
- Maximum Demand Electricity Meter 1 Pieces / (Min. Order)
- Power Factor Meter 1 Pieces / (Min. Order)
- Power Meter 1 Pieces / (Min. Order)
- Voltmeter 1 Pieces / (Min. Order)
- Ammeter 1 Pieces / (Min. Order)
- Remote Gas Meter 1 Pieces / (Min. Order)
- Prepayment Smart Meter 1 Pieces / (Min. Order)
- Prepaid Electricity Meter 1 Pieces / (Min. Order)